Product Description
OTVP Combined System is a mobile unit that integrates oil treatment and vacuum systems on a single skid, providing complete transformer service capability in one compact design.
The oil treatment section offers a variable flow rate of 500–12,000 L/h, in addition to a vacuum pump coupled with a booster pump to achieve deep vacuum for efficient dehydration and degassing. A precision heat exchanger ensures uniform heating distribution, while a three-stage filtration system provides fine purification down to 1 μm.
The vacuum section features two vacuum pumps, and one roots booster pump, delivering a primary pumping capacity of 680 m3/h and a maximum pumping speed of 2460 m3/h.
The plant can be equipped with an oil trap and cut-off valve to prevent oil intake into the booster or vacuum pump, as well as a vacuum monitoring gauge with a set point for automatic booster activation.
- Maximum heating temperature
- Minimum temperature
- 80 (176)
- 5 (41)
Operation pressure Bar (Kpa)
- Circulation pressure
- Outlet Pressure
- < 0.5 (50)
- < 1 (100)
- Pressure value in vacuum chamber during circulation.
- Pressure value in vacuum chamber under air leakage testing.
- <1 (0.75)
- <0.1 (0.075)
- Primary stage pumping speed
- Max. pumping speed
- 680
- 2460
Ultimate Pressure
- -0.1
Electric power parameters
- Total operation power, KW
- Voltage phase voltage, V.
- AC frequency, Hz
- Panel Protection
- 205
- 3Ph - 380
- 50/60
- IP55
- OTVP3K 300-1000/600-2000
- OTVP6K 600-2000
- OTVP8K 600-2000
- OTVP10K 600-2000
- OTVP12K 600-2000
- 1500-3000
- 4000-6000
- 6000-8000
- 8000-10000
- 10000-12000
- M3
- M5
- M6
- M7
- M11
- M13
- M14
- M15
- M16
- M20
- M32
- M34
- M58
- M68
- M79
- M89
- M101
- M102
- M103
- E1
- E4
- E7
- E8
- E9
- E10
- E54
- E55
- E58
- E61
- E66
- E72
- E76
- E81
- E84
- E91
- E114
- Ball Valve threaded port
- Ball Valve threaded port
- Ball Valve threaded port
- Strainer Basket
- Analog pressure gauge -1/+5 bar
- Vacuum Chamber
- Pneumatic Filter
- Oil Trap for vacuum
- Fine Filter Element 1 micron
- Quick Coupling
- Non-return Valve
- Heat Exchanger for OTVP
- Quick Coupling
- 3-way L valve
- Pneumatic actuated Butterfly valve
- Butterfly valve
- Pressure differential switch
- Pre-Filter
- After-Filter
- Limit Switch for 3-way valve
- Flow switch
- Temperature Transducer
- Solenoid valve 0.5”
- Chamber light
- Foam sensor
- External Gear Pump
- Thermostat
- Vacuum pump
- Booster pump
- Booster pump
- Flow meter DN50
- Vacuum sensor
- Heater Element for OTVP
- Capacitive level sensor
- pressure switch for pneumatic valve
- Continuous level sensor
- M01-AL001-ACCS-0015
- M01-AL001-ACCS-0088
- M01-AL001-OPT-009
- Hose set for OTVP
- Flex power cable,
- Side opening Isolation Doors
Installation
- ST-UG-FM
- MOB-ST-UG
- MOB-ST-UG-FM
- MOB-ST-UG-FM-TC
- MOB-ST-UG-FM-AC
- MOB-RD-UG
- MOB-RD-UG-XL
- MOB-RD-UG-DXL
- M01-AL001-OPT-008
- M01-AL001-OPT-012
- Stationary, with frame on shop floor.
- Mobile, on shop floor.
- Mobile on shop floor with frame.
- With frame and tarpaulin
- With frame and aluminum cover
- Mobile for road transportation.
- With single axle trailer (max. 1.5T) with tarpaulin
- With double axle trailer (max. 1.5T) with aluminum cover
- Outdoor Container 20ft
- Outdoor Container 10ft
- M01-AL001-E0090
-
M01-AL001
E0092 - MR-DGA2,3.02
- MR-DGA2,3.03
- MR-DGA5,9.05
- MR-DGA5,9.09
- M01-AL001-E0076
- M01-AL001-E0092
- Temperature and water Content instrument 0-100 ppm with accuracy ±0.02 aw/±0.2 °C,
- Temperature and water Content instrument 0-100 ppm with accuracy ±0.02 aw/±0.2 °C, and external display
- Digital Multi gases measuring system (MSENSE® DGA 2)
- Digital Multi gases measuring system (MSENSE® DGA 3)
- Digital Multi gases measuring system (MSENSE® DGA 5)
- Digital Multi gases measuring system (MSENSE® DGA 9)
- Vacuum sensor Thermovac TTR91RN for transformer, Leybold
- Pirani gauge Vacuum-meter VD84, Thyracont.
The design, manufacturing, and testing of TRAVAC oil treatment and vacuum systems are carried out in accordance with
the following international standards and directives:
- ISO 9001:2015 – Quality Management System
- CE Marking Compliance – Machinery Directive 2006/42/EC, Low Voltage Directive 2014/35/EU, and EMC Directive 2014/30/EU
- IEC 60204-1 – Electrical Equipment of Machines
- IEC 60034 – Rotating Electrical Machines
- EN 61010-1 – Safety Requirements for Electrical Equipment
- EN ISO 12100 – Safety of Machinery – Risk Assessment Principles









What people say
Integer consectetur arcu a purus dignissim elementum. Aenean quis urna non eros suscipit pretium cursus non ipsum. Nam ultrices laoreet semper.
Peter Parker
Integer consectetur arcu a purus dignissim elementum. Aenean quis urna non eros suscipit pretium cursus non ipsum. Nam ultrices laoreet semper.
Kevin Rogers
Integer consectetur arcu a purus dignissim elementum. Aenean quis urna non eros suscipit pretium cursus non ipsum. Nam ultrices laoreet semper.
Jason Bright
Interested in This Product?
Send us your inquiry about this product and our team will get back to you shortly with all the details you need.